Lindy 32665 User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 17
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
2928
APPENDIX SMS COMMANDS LISTCHAPTER 6 MAIN TECHNICAL
Input Power Socket 110 – 250v / 50hZ
Output Power Socket Relay Max 13 Amp
Operating Temperature -10ºC to +50ºC
Store Temperature -20ºC to + 60ºC
Relative Humidity 10-90% Without Condensation
Communication Protocols GSM Phase 2/2+ (including data operation)
Data Interface GSM SIM 1.8V / 3.0V Socket
External Temperature Sensor -10ºC to +50ºC
GSM Working Band EGSM900, DCS1800
Category Function Command
Time Set the socket time #152#
Define the
Users
Add a master number #00#
Change the master number #14#NewMasterNumber#
Add an additional number #06#AdditionalNumber#
Add several numbers
#06#AdditionalNumber1
#...#AdditionalNumber4#
Delete an additional number #113#AdditionalNumber#
Delete several additional numbers
#113#AdditionalNumber1
#...#AdditionalNumber4#
Delete all additional numbers #113#
Switching
on/off output
manually
Switch the socket output ON
(master)
#01#
Switch the socket output OFF
(master)
#02#
Switch the socket output ON
(additional users)
#01#Password#
Switch the socket output OFF
(additional users)
#02#Password#
Enable the output to switch ON/OFF
by calling
#18#1#
Disable the output to switch ON/OFF
by calling (Default)
#18#0#
Delay
Control
Delay switching ON the output #138#1#Minutes#
Delay switching OFF the output #138#0#Minutes#